Resistance Coefficients of Fittings |
|||||||
| Fitting |
Nominal Pipe Size |
||||||
|
2 |
3 |
4 |
6 |
8 |
10 |
12 and above |
|
|
Resistance Coefficient K |
|||||||
| Gate Valves |
0.15 |
0.14 |
0.14 |
0.12 |
0.11 |
0.11 |
0.10 |
| Elbow (r/d=2) |
0.23 |
0.22 |
0.20 |
0.18 |
0.17 |
0.17 |
0.16 |
| Swing Check Valve |
1.9 |
1.8 |
1.7 |
1.5 |
1.4 |
1.4 |
1.3 |
|
|
|||||||
| Pipe Exit - Sharp or Rounded |
1 |
||||||
|
Typical Hazen and Williams Friction Factors C |
|||||||
| Type of Pipe |
Steel |
Concrete |
Cast Iron |
|
. |
||
| C Factor New or Smooth |
130 - 150 |
120 - 150 |
130 - 150 |
||||
| C Factor Corroded or Rough |
80 |
85 |
80 |
||||
| C Factor (Typical for Design) |
110 |
120 |
100 |
Design min. |
Design max |
||
| C Factor Range Recommended for Calculating Required Pump TDH |
|
|
min. 120 |
max.140 |
|||